Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 643
Filtrar
1.
J Robot Surg ; 17(6): 3035-3038, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37610537

RESUMO

The Versius Surgical System is a next generation soft-tissue robot with instrument and endoscope arms split into individual modules. Despite its similarities with previous systems, the basic changes in the design raise concerns relating to the feasibility of the set-up for the different approaches in robotic head and neck surgery procedures. We used a complete unit with a surgeon's console and four modules on a training mannequin to depict the different configurations in the operating room. We tested transoral robotic surgery and the four basic configurations for the remote access to the neck: transoral/transvestibular, retroauricular, axillary and bilateral axillo-breast approaches. We obtained a high quality simulation for transoral robotic surgery, as well as for the usual remote access approaches, except for the axillary approach. We were able to obtain an optimal distribution of the modules around the surgical table and an adequate configuration of the joints allowing the instruments to reach their targets. The Versius Surgical System might be an alternative device for robotic procedures in head and neck surgery, although this needs to be proved in a clinical setting.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos de Viabilidade , Tireoidectomia/métodos , Cadáver
2.
Zhongguo Gu Shang ; 36(5): 414-9, 2023 May 25.
Artigo em Chinês | MEDLINE | ID: mdl-37211931

RESUMO

OBJECTIVE: To compare the short-term clinical efficacy and radiologic differences between oblique lateral interbody fusion(OLIF) and minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) for degenerative lumbar spondylolisthesis. METHODS: A retrospective analysis was performed on 58 patients with lumbar spondylolisthesis treated with OLIF or MIS-TLIF from April 2019 to October 2020. Among them, 28 patients were treated with OLIF (OLIF group), including 15 males and 13 females aged 47 to 84 years old with an average age of (63.00±9.38) years. The other 30 patients were treated with MIS-TLIF(MIS-TLIF group), including 17 males and 13 females aged 43 to 78 years old with an average age of (61.13±11.10) years. General conditions, including operation time, intraoperative blood loss, postoperative drainage, complications, lying in bed, and hospitalization time were recorded in both groups. Radiological characteristics, including intervertebral disc height (DH), intervertebral foramen height (FH), and lumbar lordosis angle (LLA), were compared between two groups. The visual analogue scale (VAS) and Oswestry disability index (ODI) were used to evaluate the clinical effect. RESULTS: The operation time, intraoperative blood loss, postoperative drainage, lying in bed, and hospitalization time in OLIF group were significantly less than those in the MIS-TLIF group (P<0.05). The intervertebral disc height and intervertebral foramen height were significantly improved in both groups after the operation (P<0.05). The lumbar lordosis angle in OLIF group was significantly improved compared to before the operation(P<0.05), but there was no significant difference in the MIS-TLIF group before and after operation(P>0.05). Postoperative intervertebral disc height, intervertebral foramen height, and lumbar lordosis were better in the OLIF group than in the MIS-TLIF group (P<0.05). The VAS and ODI of the OLIF group were lower than those of the MIS-TLIF group within 1 week and 1 month after the operation (P<0.05), and there were no significant differences in VAS and ODI at 3 and 6 months after the operation between the two groups(P>0.05). In the OLIF group, 1 case had paresthesia of the left lower extremity with flexion-hip weakness and 1 case had a collapse of the endplate after the operation;in the MIS-TLIF group, 2 cases had radiation pain of lower extremities after decompression. CONCLUSION: Compared with MIS-TLIF, OLIF results in less operative trauma, faster recovery, and better imaging performance after lumbar spine surgery.


Assuntos
Lordose , Fusão Vertebral , Espondilolistese , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto , Estudos Retrospectivos , Espondilolistese/diagnóstico por imagem , Espondilolistese/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Lordose/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fusão Vertebral/métodos , Resultado do Tratamento , Perda Sanguínea Cirúrgica , Hemorragia Pós-Operatória
3.
International Journal of Surgery ; (12): 433-436, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-989477

RESUMO

In recent years, with the development and maturity of endoscopic technique, endoscopic spinal surgery represented by water media and optical rigid endoscope has been widely used in the treatment of many disorders in the cervical, thoracic and lumbar spine. Endoscopic spinal surgery shows similar clinical effects as traditional open surgery or other minimally invasive procedures, and is favored by spinal surgeons due to its advantages of less trauma and rapid recovery after surgery. However, the large-scale application of endoscopic technique brings problems such as non-standard nomenclature and unreasonable indications. Therefore, this article will summarize the surgical nomenclature and indications of endoscopic spinal surgery, in order to provide a reference for spinal surgeons to understand and apply endoscopic technology reasonably.

4.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-981707

RESUMO

OBJECTIVE@#To compare the short-term clinical efficacy and radiologic differences between oblique lateral interbody fusion(OLIF) and minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) for degenerative lumbar spondylolisthesis.@*METHODS@#A retrospective analysis was performed on 58 patients with lumbar spondylolisthesis treated with OLIF or MIS-TLIF from April 2019 to October 2020. Among them, 28 patients were treated with OLIF (OLIF group), including 15 males and 13 females aged 47 to 84 years old with an average age of (63.00±9.38) years. The other 30 patients were treated with MIS-TLIF(MIS-TLIF group), including 17 males and 13 females aged 43 to 78 years old with an average age of (61.13±11.10) years. General conditions, including operation time, intraoperative blood loss, postoperative drainage, complications, lying in bed, and hospitalization time were recorded in both groups. Radiological characteristics, including intervertebral disc height (DH), intervertebral foramen height (FH), and lumbar lordosis angle (LLA), were compared between two groups. The visual analogue scale (VAS) and Oswestry disability index (ODI) were used to evaluate the clinical effect.@*RESULTS@#The operation time, intraoperative blood loss, postoperative drainage, lying in bed, and hospitalization time in OLIF group were significantly less than those in the MIS-TLIF group (P<0.05). The intervertebral disc height and intervertebral foramen height were significantly improved in both groups after the operation (P<0.05). The lumbar lordosis angle in OLIF group was significantly improved compared to before the operation(P<0.05), but there was no significant difference in the MIS-TLIF group before and after operation(P>0.05). Postoperative intervertebral disc height, intervertebral foramen height, and lumbar lordosis were better in the OLIF group than in the MIS-TLIF group (P<0.05). The VAS and ODI of the OLIF group were lower than those of the MIS-TLIF group within 1 week and 1 month after the operation (P<0.05), and there were no significant differences in VAS and ODI at 3 and 6 months after the operation between the two groups(P>0.05). In the OLIF group, 1 case had paresthesia of the left lower extremity with flexion-hip weakness and 1 case had a collapse of the endplate after the operation;in the MIS-TLIF group, 2 cases had radiation pain of lower extremities after decompression.@*CONCLUSION@#Compared with MIS-TLIF, OLIF results in less operative trauma, faster recovery, and better imaging performance after lumbar spine surgery.


Assuntos
Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto , Estudos Retrospectivos , Espondilolistese/cirurgia , Vértebras Lombares/cirurgia , Lordose/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fusão Vertebral/métodos , Resultado do Tratamento , Perda Sanguínea Cirúrgica , Hemorragia Pós-Operatória
5.
Cancer Research and Clinic ; (6): 228-233, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-996216

RESUMO

With the continuous development of endoscopic technology, more and more early-stage colorectal cancer and precancerous lesions have been found by endoscopy, and endoscopic treatment has dominated the treatment of early-stage colorectal cancer for its characteristics of small trauma, rapid recovery and good effect. At present, there are many methods of endoscopic treatment, but their indications are still controversial, and some new technologies still need further verified. Based on the latest guidelines at home and abroad and some hot issues, this article reviews the progress of endoscopic treatment of early-stage colorectal cancer and precancerous lesions, mainly including the indications of various endoscopic treatment methods, some important technical improvement of endoscopic treatment methods, and the application of some new endoscopic treatment technologies, in order to provide some references for the minimally invasive treatment of early-stage colorectal cancer and precancerous lesions.

6.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-992742

RESUMO

Minimally invasive treatment is the development trend in surgical techniques for pelvic fractures. There have been numerous minimally invasive techniques for pelvic fractures, each having its own advantages. This paper reviews the literature recently published at home and abroad concerning minimally invasive treatment of pelvic fractures so as to summarize the existing minimally invasive techniques for the fractures and their supporting theories, hoping traumatic orthopedists to know more about the minimally invasive techniques. As a result, Chinese traumatic orthopedists may formulate personalized treatment protocols to suit the specific condition of each patient so that the surgical invasion can be minimized and the intraoperative and postoperative complications reduced.

7.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-992740

RESUMO

Objective:To investigate the feasibility and clinical efficacy of percutaneous anterior column screwing assisted by blocking screws for pelvic and acetabular fractures.Methods:A retrospective analysis was conducted of the 13 patients who had been admitted from July 2019 to April 2022 for pelvic and acetabular fractures. There were 8 males and 5 females with an age of (49.1±13.3) years, 7 acetabular fractures (6 on one side and 1 on both sides; by the Letournel-Judet classification: 5 anterior column fractures on 6 sides, and 2 transverse and posterior wall fractures on 2 sides), and 6 pelvic fractures (5 complicated with pelvic posterior ring fracture; by the Tile classification: 1 case of type B2, 3 cases of type C1, and 2 cases of type C2). According to the anatomic zones of the anterior column, 5 fractures were at zone Ⅲ, 3 ones at zone Ⅳ, and 6 ones at zone Ⅴ. The time from injury to surgery ranged from 3 to 14 days, averaging (8.2±2.9) days. Anterograde anterior column screwing assisted by blocking screws was performed for all the 13 patients; the posterior ring was fixated with percutaneous sacroiliac joint screws for the 5 patients complicated with pelvic posterior ring fracture. The surgical time, intraoperative fluoroscopy frequency, and intraoperative bleeding volume for insertion of anterior column screws, fracture reduction quality, and hip joint function at the last follow-up were recorded.Results:A total of 14 anterior column screws were inserted percutaneously in the 13 patients. For insertion of anterior column screws, the surgical time was (65.0±10.2) min, the intraoperative fluoroscopy frequency (63.5±14.5) times, and the intraoperative bleeding volume for each screw less than 30 mL. All the incisions healed primarily after surgery, without such complications as iatrogenic neurovascular injury or poor wound healing. All the 13 patients were followed up for (11.1±2.2) months after surgery. In the patient with bilateral acetabular anterior column fractures for which 2 anterior column screws had been inserted, one screw had to be removed due to its displacement at 1 month after surgery; no such complications as loosening of internal fixation or fracture re-displacement was found in the other patients. All fractures healed after (10.2±2.1) months. According to the Matta scoring for quality of fracture reduction, 7 sides were excellent, 5 sides good, and 2 sides poor; according to the Majeed scoring for the 6 patients with pelvic fracture at the last follow-up, the efficacy was rated as excellent in 4 cases and as good in 2 ones; according to the modified Merle d'Aubigné & Postel scoring for the 7 patients with 8 acetabular fractures at the last follow-up, the efficacy was rated as excellent in 4 hips, as good in 3 hips, and as fair in 1 hip.Conclusion:For pelvic and acetabular fractures, minimally invasive percutaneous anterior column screwing assisted by blocking screws can result in fine clinical efficacy, in addition to its easy procedures, safety and reliability.

8.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-992738

RESUMO

Objective:To explore the clinical efficacy of a retrograde pubic ramus intramedullary nail (RPRIN) in the treatment of anterior pelvic ring fractures.Methods:A retrospective study was conducted to analyze the 14 patients with anterior pelvic ring fracture who had been treated and followed up at Department of Traumatic Surgery, Tongji Hospital From June 2020 to February 2021. There were 10 males and 4 females with an age of (44.8±12.5) years. By the AO/OTA classification for pelvic fractures, 5 cases were type 61-A, 4 cases 61-B, and 5 cases type 61-C; by the Nakatani classification, 1 case belonged to unilateral zone Ⅰ fracture, 5 cases to unilateral zone Ⅱ fracture, 2 cases to unilateral zone Ⅲ fracture, 3 cases to right zone Ⅱ and left zone Ⅲ fracture, 2 cases to zone Ⅲ fracture on both left and right sides, and 1 case to zone Ⅱ fracture on both sides. The time from injury to operation was (7.8±1.8) days. All the anterior pelvic ring fractures were fixated with a RPRIN. The time and fluoroscopic frequency for placement of every single RPRIN, quality of fracture reduction, and pelvic function and incidence of postoperative complications at the last follow-up were recorded.Results:A total of 18 RPRINs were placed in the 14 patients. For placement of each RPRIN, the time was (35.9±8.6) min, and the fluoroscopic frequency (22.8±1.9) times. No complications such as infection occurred at any surgical incision after RPRIN placement. According to the Matta scoring, the quality of postoperative fracture reduction was assessed as excellent in 7 cases, as good in 5 cases and as fair in 2 cases. The 14 patients were followed up for (18.1+1.5) months. Their X-ray and CT images of the pelvis at the last follow-up showed that the fractures healed well and the intramedullary nails were placed in the cortical bone of the anterior ring of the pelvis. According to the Majeed scoring at the last follow-up, the pelvic function was assessed as excellent in 10 cases, as good in 3 cases and as fair in 1 case. One patient reported discomfort during squatting 2 months after operation but the symptom improved 3 months later without any special treatment. No patient experienced such complications as displacement or slippage of RPRIN, or pain at the insertion site.Conclusion:RPRIN is effective in the treatment of anterior pelvic ring fractures, showing advantages of small surgical incision, limited intraoperative fluoroscopy and short operation time.

9.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-992727

RESUMO

Objective:To compare the clinical effects between proximal humerus internal locking system (PHILOS) inverted and a posterior single plate in the anterior percutaneous minimally invasive internal fixation for distal humeral shaft fractures.Methods:A retrospective study was conducted to analyze the data of 65 patients with distal humeral shaft fracture who had been treated from January 2018 to May 2021 at Department of Orthopaedics, The Second Hospital of Fuzhou. The patients were assigned into 2 groups according to different treatment methods. In the observation group of 30 cases subjected to anterior percutaneous minimally invasive internal fixation with PHILOS inverted: 20 males and 10 females with an age of (41.5±11.6) years; type A in 5 cases, type B in 14 cases, and type C in 11 cases by AO fracture classification. In the control group of 35 cases subjected to anterior percutaneous minimally invasive internal fixation with a posterior single plate: 23 males and 12 females with an age of (39.9±11.2) years; type A in 7 cases, type B in 17 cases, and type C in 11 cases by AO fracture classification. The preoperative general data, operation time, intraoperative blood loss, total incision length, fracture healing time, and shoulder and elbow VAS scores, Constant-Murley shoulder function score, Mayo elbow performance score (MEPS), and complications at the last follow-up were recorded and compared between the 2 groups.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). There were no significant differences either in operation time, fracture healing time, or shoulder or elbow VAS pain score, Constant-Murley shoulder function score, or MEPS at the last follow-up between the 2 groups ( P>0.05). The intraoperative blood loss was (59.7±26.6) mL in the observation group and (165.7±86.4) mL in the control group, and the total incision length was (10.7±2.1) cm in the observation group and (18.6±2.7) cm in the control group, showing statistically significant differences between the 2 groups ( P<0.01). There was no injury to the radial nerve or musculocutaneous nerves, incision infection or fracture nonunion in the observation group. There were 4 cases of iatrogenic radial nerve injury, 2 cases of incision infection and 1 case of fracture nonunion in the control group, yielding a complication rate of 20.0% (7/35). The difference in the incidence of complications was significant between the 2 groups ( P<0.01). Conclusion:In the treatment of distal humeral shaft fracture with anterior percutaneous minimally invasive internal fixation, PHILOS inverted has advantages of less soft tissue damage, less intraoperative bleeding, and a lower risk of iatrogenic radial nerve injury than the posterior single plate.

10.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-992717

RESUMO

Objective:To compare the short-term efficacy between our self-designed intelligent robot-assisted minimally invasive reduction system and conventional freehand reduction assisted by fluoroscopy in the treatment of unstable pelvic fractures by robot or fluoroscopy-assisted internal fixation with percutaneous screws.Methods:A prospective randomized controlled trial was conducted to include eligible 35 patients with unstable pelvic fracture who were admitted to Department of Orthopaedic Trauma, Beijing Jishuitan Hospital from December 2021 to October 2022. They were randomized into 2 groups. The observation group[17 cases, 10 males and 7 females with an age of (44.0±17.4) years] was treated with robot-assisted minimally invasive reduction, followed by robot-assisted or fluoroscopic internal fixation with percutaneous screws; the control group[18 cases, 12 males and 6 females with an age of (38.8±15.0) years] was treated with freehand reduction assisted by fluoroscopy, followed by robot-assisted or fluoroscopic internal fixation with percutaneous screws. The 2 groups were compared in terms of operation time, intraoperative bleeding, successful reduction, reduction quality, incidence of surgical complications and postoperative functional scores.Results:The 2 groups were comparable because there were no significant differences in the preoperative general data between them ( P>0.05). The intraoperative fluoroscopy frequency[(32.4±17.5) times] and fluoroscopy time [(19.8±10.4) s] in the observation group were significantly lower or shorter than those in the control group [(60.8±26.6) times and (38.2±16.1) s], and the rate of successful reduction in the observation group was 100.0% (17/17), significantly higher than that in the control group[72.2% (13/18)] ( P<0.05). There was no significant difference between the 2 groups in intraoperative bleeding, operation time, reduction error, excellent and good rate of reduction after operation by Matta scoring, or Majeed functional score at 12 weeks after operation ( P>0.05). Conclusion:In the treatment of unstable pelvic fractures, since our self-designed intelligent robot-assisted minimally invasive reduction system can plan autonomously the reduction paths and accomplish minimally invasive reduction of the fracture with 3D images real-time monitoring, it is advantageous over conventional reduction methods in a higher success rate and less radiation exposure.

11.
Zhongguo Gu Shang ; 35(8): 775-8, 2022 Aug 25.
Artigo em Chinês | MEDLINE | ID: mdl-35979773

RESUMO

OBJECTIVE: To retrospectively analyze clinical effect of 3D mirror printing combining with minimally invasive percutaneous plate osteosynthesis(MIPPO) technology in the treatment of adult clavicle fracture. METHODS: The clinical data of 32 adult patients with collarbone AllmanⅠdisplacement of fracture who had undergone the combination of 3D mirror printing with MIPPO technology treatment were collected from October 2019 to October 2020. There were 19 males and 13 females, aged from 19 to 55 years old with an average of(34.12±16.42) years old. According to Allman classification, there were 14 cases of AllmanⅠb and 18 cases of AllmanⅠc. Fracture occurred on the left in 17 cases and on the right in 15 cases. Postoperative complications, operation time, incision length, intraoperative blood loss, the number of fluoroscopies, fracture healing time of all patients were retrospectively analyzed, and the curative effect was evaluated by Constant-Murley shoulder joint score before operation, 1 and 6 months after operation. RESULTS: All the 32 patients were followed up for 6 to 8 months, with an average of (6.67±2.13) months. All the patients did not have postoperative complications such as incision infection and skin numbness in the operating area. The operation time was (35.37±4.28) min. The incision length was (3.78±0.45) cm. Intraoperative blood loss was(37.23±4.76) ml. The number of fluoroscopies was(3.12±0.47) times. Fracture healing time was (8.18±2.58) weeks. Constant-Murley shoulder joint score of the affected side at 1 and 6 months after operation was 81.08±3.92 and 98.03±1.05 respectively, which had a significant difference compared with 54.62±5.25 before operation(P<0.05). According to Constant-Murley shoulder function score at 6 months after operation, 30 cases were excellent and 2 cases were good. CONCLUSION: 3D mirror printing can effectively assist MIPPO technique in the treatment of adult clavicle AllmanⅠdisplaced fracture. It not only has the advantages of less trauma and fewer complications of the MIPPO technique, but also can further shorten the operation time and improve the operation maneuverability. It is a better method in the treatment of adult clavicle AllmanⅠdisplaced fracture.


Assuntos
Clavícula , Fraturas Ósseas , Adolescente , Adulto , Perda Sanguínea Cirúrgica , Placas Ósseas , Clavícula/lesões , Clavícula/cirurgia , Feminino , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Impressão Tridimensional , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
12.
Zhongguo Gu Shang ; 35(4): 357-60, 2022 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-35485154

RESUMO

OBJECTIVE: To explore feasibility of closed reduction technique under monitoring of C-arm and three screws in the fixation of abduction and insertion femoral neck fracture. METHODS: Seventeen patients with abduction and insertion femoral neck fracture operated from January 2014 to December 2019 were analyzed retrospectively, including 10 males and 7 females, aged from 21 to 59(42.09±7.30) years old. According to preoperative X-ray and CT data, angle of retroversion and abduction displacement of femoral head were determined. Two 2 mm diameter Kirschner wires crossed and gently knocked into the bone of the acetabular roof from outside and front of femoral head. The proximal fracture segment was fixed on the acetabulum. Under the monitoring of C-arm, lower limb (distal fracture segment) was gradually rotated inward and retracted against direction of fracture displacement, three cannulated screws were used for internal fixation after anatomical reduction of the distal fracture end and the proximal fracture end. Garden index was evaluated, postoperative complications were observed, and Harris functional score was performed. RESULTS: All 17 cases of femoral neck fracture with abduction and insertion were successfully completed closed reduction and internal fixation. The operation time was 36 to 68(43.87±7.63) min and intraoperative bleeding was 15 to 50(28.36±5.93) ml. The quality of fracture reduction was evaluated by garden index during operation. There were 12 cases of anatomical reduction, 5 cases of acceptable reduction, and no cases of unsuccessful reduction were changed to open reduction. 17 cases were followed up for 3 to 41(27.5±8.4) months. There were no complications such as femoral head necrosis, fracture nonunion, hip impingement and femoral neck shortening. MR examination showed no femoral head necrosis and articular cartilage injury. Two years after operation, Harris score of hip joint was excellent in 13 cases and good in 4 cases. CONCLUSION: Closed reduction and three screws internal fixation can obtain good anatomical reduction rate and therapeutic effect in the treatment of abduction and insertion femoral neck fracture.


Assuntos
Fraturas do Colo Femoral , Adulto , Fios Ortopédicos , Feminino , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
13.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-956611

RESUMO

Objective:To compare closed reduction and intramedullary nailing versus open reduction and locking plate fixation in the treatment of middle and upper humeral fractures.Methods:A retrospective case-control study was conducted to analyze the clinical data of 62 patients with middle and upper humeral fracture who had been treated at Department of Orthopaedics, The First People's Hospital of Jinmen and at Department of Orthopedics, General Hospital of PLA Central Theater from October 2017 to February 2021. There were 35 males and 27 females, aged from 27 to 86 years. The left side was affected in 24 cases and the right side in 38 cases. All fractures were fresh. According to the AO classification, 16 cases were type A, 32 type B, and 14 type C. Of the patients, 29 were treated with closed reduction and intramedullary nailing (intramedullary nail group) and 33 with open reduction and locking plate fixation (locking plate group). The length of incision, operation time, intraoperative blood loss, hospital stay, fracture healing and complications were recorded and compared between the 2 groups. The pain degree was evaluated by visual analogue scale (VAS) at one week and one month after operation, and the functional recovery of the shoulder was evaluated by Constant-Murley score at one month and 12 months after operation.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). The intramedullary nail group was followed up for 12 to 29 months and the locking plate group for 15 to 50 months. In the intramedullary nail group, the length of incision [(4.1±0.7) cm], operation time [(58.3±7.7) min], intraoperative blood loss [(52.7±6.5) mL], and hospital stay [(7.3±1.5) d] were significantly less than those in the locking plate group [(21.7±2.3) cm, (95.8±11.7) min, (237.4±14.9) ml, and (12.3±1.7) d] ( P<0.05). The fracture healing time in the intramedullary nail group was (5.0±1.9) months, significantly longer than that in the locking plate group [(3.5±1.7) months] ( P<0.05). The VAS scores at one week and one month after operation in the intramedullary nail group [(2.8±0.3) points and (1.2±0.5) points] were significantly lower than those in the locking plate group [(4.3±0.4) points and (1.6±0.5) points], and the Constant-Murley score at one month after operation in the intramedullary nail group [(63.5±7.4) points] was significantly higher than that in the locking plate group [(54.3±6.9) points] ( P<0.05). However, at 12 months after operation, there was no significant difference in the Constant-Murley score between the 2 groups ( P>0.05). In both groups, the VAS score at one month after operation was significantly lower than that at one week after operation while the Constant-Murley score at 12 months after operation was significantly higher than that at one week after operation ( P<0.05). In the intramedullary nail group, intraoperative distal refracture happened in one case; in the locking plate group, incision infection occurred in one case and postoperative radial nerve injury in another. There was no significant difference in the incidence of complications between the 2 groups [3.4% (1/29) versus 6.1% (2/33)] ( P>0.05). Conclusion:In the treatment of middle and upper humeral fractures, compared with open reduction and locking plate fixation, closed reduction and intramedullary nailing shows advantages of a smaller surgical incision, shorter operation time, less intraoperative blood loss, shorter hospital stay and faster functional recovery.

14.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-956610

RESUMO

Objective:To compare the clinical effects of minimally invasive reduction through a bone tunnel combined with Jail screwing and those of posterolateral locking plating in the treatment of simple posterolateral tibial plateau fractures.Methods:A retrospective analysis was conducted of the data of 48 patients who had been operatively treated and completely followed up at Department of Orthopedics, Suqian Hospital of Nanjing Drum Tower Hospital Group for simple posterolateral tibial plateau fractures from October 2016 to October 2020. There were 26 males and 22 females, aged from 35 to 68 years. They were divided into a minimally invasive group (25 cases subjected to minimally invasive reduction through a bone tunnel combined with Jail screwing) and an incision group (23 cases subjected to posterolateral locking plating) according to their surgical methods. The operation time, incision length, intraoperative blood loss, fracture healing time, cumulative fluoroscopy time, hospital stay and posterior inclination angles of the tibial plateau and Hospital for Special Surgery (HSS) knee function scores at 1, 3, 6, 9, and 12 months after operation were compared between the 2 groups. Complications in the 2 groups of patients were recorded.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). The 48 patients were followed up for 12 to 36 months (average 16.5 months). The minimally invasive group was significantly better than the incision group in operation time [(42.6±9.1) min versus (65.7±11.5) min], incision length [(4.0±0.4) cm versus (15.0±1.5) cm], intraoperative blood loss[(22.6±5.8) mL versus (31.5±8.8) mL], hospital stay [(7.6±1.4) d versus (11.1±2.4) d], and HSS score one month after operation [(84.8±1.9) points versus (72.9±4.1) points], but the cumulative fluoroscopy time in the incision group [(4.1±1.4) s]was significantly less than that in the minimally invasive group [(22.3±4.2) s] ( P<0.05). There were no significant differences in fracture healing time, HSS scores at 3, 6, 9, or 12 months after operation, or posterior inclination angle of the tibial plateau between the 2 groups ( P>0.05). There were no such complications as wound infection, vascular injury, internal fixation failure, nonunion or malunion of fractures in either of the 2 groups. Two cases in the incision group presented with symptoms of common peroneal nerve injury but recovered 3 months after operation. Conclusions:Although both minimally invasive reduction through a bone tunnel combined with Jail screwing and posterolateral locking plating can achieve satisfactory outcomes in the treatment of simple posterolateral tibial plateau fractures, the minimally invasive technique is preferable because it shows the advantages of a smaller incision, less bleeding, shorter operation time, a lower operation risk, quicker postoperative recovery and shorter hospital stay.

15.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-956598

RESUMO

Objective:To explore the efficacy and safety of TiRobot combined with three-dimensional imaging in the minimally invasive surgery for pelvic fractures.Methods:A retrospective analysis was conducted of the 40 patients with pelvic fracture who had been treated by fixation with S1 and S2 sacroiliac screws at Department of Orthopaedics and Traumatology, Yangjiang People's Hospital from January 2019 to May 2021. They were divided into 2 groups according to their treatment methods. In the TiRobot group of 20 cases subjected to percutaneous sacroiliac screw fixation assisted by TiRobot combined with three-dimensional imaging, there were 13 males and 7 females with an age of (38.2 ± 8.8) years. In the manual group of 20 cases subjected to fixation with manual placement of sacroiliac screws under conventional C-arm fluoroscopy, there were 11 males and 9 females with an age of (37.3 ± 9.2) years. The 2 groups were compared in terms of fluoroscopy time for screw placement, guide needle adjustment, operation time, intraoperative blood loss, visual analogue scale (VAS) 72 hours after operation, postoperative hospital stay, time to ambulation, excellent to good rate of screw placement, complication rate, fracture union time, Majeed score at 6 months after operation, and excellent to good rate of functional evaluation.Results:There was no significant difference between the 2 groups in their preoperative general data, showing they were comparable ( P > 0.05). In the TiRobot group, fluoroscopy time for screw placement [(8.2 ± 2.9) s], guide needle adjustment [(0.4 ± 0.2) times], operation time [(67.4 ± 5.5) min], and intraoperative blood loss [(36.5 ± 8.0) mL] were significantly less than those in the manual group [(40.4 ± 4.5) s, (8.6 ± 0.7) times, (78.4 ± 7.2) min, and (41.6 ± 7.8) mL], postoperative VAS [3.0 (4.0, 5.0) points] was significantly lower than that in the manual group [4.0 (5.0, 6.0) points], the excellent to good rate of screw placement (100%, 40/40) was significantly higher than that in the manual group (85.0%, 34/40), and the complication rate (5.0%,1/20) was significantly lower than that in the manual group (35.0%, 7/20) (all P < 0.05). There was no significant difference between the 2 groups in postoperative hospital stay, time to ambulation, fracture union time, Majeed score, or excellent to good rate of functional evaluation ( P > 0.05). Conclusion:In the minimally invasive surgery for pelvic fractures, TiRobot combined with three-dimensional imaging leads to positive outcomes, because it can reduce operation time and radiation exposure, improve accuracy of screw placement, and increase safety.

16.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-956571

RESUMO

Objective:To compare percutaneous cannulated screw (PCS) fixation and plating via a minimally invasive longitudinal approach (MILA) after closed reduction for the treatment of intra-articular tongue-type calcaneal fractures.Methods:A retrospective analysis was conducted of the 67 patients with intra-articular tongue-type calcaneal fracture who had been treated at Department of Orthopedics, The Third Hospital of Peking University from May 2017 to May 2020. They were 56 males and 11 females, 19 to 58 years of age (average, 34.5 years). Of them, 32 were treated by the PCS fixation after closed reduction (PCS group) and 35 by the MILA plating after closed reduction (MILA group). The operation time, preoperative time, post-operative hospital stay, blood loss and postoperative complications were recorded and compared between the 2 groups. The calcaneal length, width and height, Gissane angle, B?hler angle, varus angle, valgus angle and visual analog scale (VAS) were compared between the 2 groups at preoperation, immediate postoperation, 3 months postoperation, and the last follow-up. The American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score was used at 3 months postoperation and the last follow-up to evaluate the function of the injured hindfoot.Results:There was no significant difference in the preoperative general data between the PCS group and the MILA group, showing they were comparable ( P>0.05). All patients were followed up for an average of 18.5 months (from 15 to 25 months). For the PCS group and the MILA group, respectively, the operation time was 60.5 (51.5, 68.0) min and 86.0 (78.0, 96.0) min, the blood loss 10 (5.0, 20.0) mL and 20 (15, 25) mL, the postoperative hospital stay 1 (1.0, 1.8) d and 2 (2, 3) d, the calcaneal width at immediate postoperation (43.8±4.4) mm and (40.6±2.8) mm, the calcaneal width at 3 months postoperation 43.8 (39.6, 48.3) mm and 41.5 (38.8, 44.5) mm, the calcaneal width at the last follow-up 44.2 (40.2, 48.0) mm and 41.3 (39.0, 44.3) mm, the VAS at the last follow-up 5.0 (5.0, 5.0) and 6.0 (5.0, 6.0). The comparisons of the above items showed significant differences between the 2 groups (all P<0.05). No significant differences were observed between the 2 groups in the calcaneal length or height, Gissane or B?hler angle, AOFAS hindfoot score, or complication rate (all P>0.05). Conclusions:In the treatment of tongue-type calcaneal fractures, after closed reduction, the PCS fixation can shorten operation time and postoperative hospital stay, and reduce intraoperative blood loss and postoperative pain, but the MILA plating is more advantageous in restoring the calcaneal width.

17.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-956547

RESUMO

Objective:To investigate the short-term efficacy of anatomical calcaneal external fixator in the treatment of calcaneal fractures.Methods:A retrospective study was conducted of the 9 patients with calcaneal fracture who had been admitted to Department of Orthopedics, 920 Hospital of the PLA Joint Logistics Support Force between September 2019 and March 2020. There were 7 males and 2 females, aged from 23 to 66 years (mean, 41.3 years). The injury was caused by a fall from a height in 6 cases and a traffic accident in 3 cases. By the Sanders classification, there were 2 cases of type ⅡB, 2 cases of type ⅢAC, 3 type Ⅲ AB, one of type Ⅲ BC and one type Ⅳ. By the AO grading for closed soft tissue injury in the 8 closed fractures, there were 5 cases of grade Ⅰ and 3 cases of grade Ⅱ. The one open fracture was type ⅢB by the Gustilo-Anderson classification and treated with skin flap repair after debridement. All the 9 patients were treated with an anatomic calcaneal external fixator during stage-one or stage-two surgery (8 patients in stage-one and one in stage-two). The fracture union time for the patients was recorded; the ankle and hindfoot score of American Orthopedic Foot and Ankle Society (AOFAS) and the protocol of Association for the Study and Application of the Method of Ilizarov (ASAMI) were used at the last follow-up to assess the short-term efficacy.Results:Postoperative follow-up for the 9 patients ranged from 6 to 18 months (mean, 9.8 months). The duration of fracture union in the 9 patients ranged from 2 to 4 months (mean 2.8 months). The AOFAS ankle and hindfoot score at last follow-up ranged from 79 to 93 points (mean, 84.7 points) for the male patients (6 excellent and one good), and from 82 to 91 points (mean, 86.5 points) for the female patients (one excellent and one good). According to the ASAMI protocol at last follow-up, the short-term efficacy was rated as excellent in 6 cases, as good in 2 cases and as fair in one. The patients with closed fracture could get out of bed for rehabilitation on day 3 after surgery. None of the patients experienced such complications as pin tract infection and osteomyelitis during follow-up.Conclusion:The anatomic external calcaneal fixator demonstrates fine short-term efficacy in the treatment of calcaneal fractures, due to its advantages like anatomical configuration, a limited number of implants, and a possibility of partial weight-bearing for exercises on the third postoperative day.

18.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-956546

RESUMO

Objective:To explore the clinical efficacy of internal fixation with a reduction plate assisted by our self-designed lower extremity fracture traction reduction device for tibial plateau fractures of Schatzker type Ⅵ.Methods:A retrospective study was conducted of the 32 patients with tibial plateau fracture of Schatzker type Ⅵ who had been treated at Orthopaedic Department, Mindong Hospital Affiliated to Fujian Medical University from April 2018 to July 2021. Depending on their treatments, they were divided into 2 groups. In the control group of 16 cases subjected to open reduction and internal fixation with manual traction, there were 9 males and 7 females with an age of 50.0±11.7 years; in the observation group of 16 cases subjected to internal fixation with a reduction plate assisted by our self-designed lower extremity fracture traction reduction device, there were 8 males and 8 females with an age of 54.6±11.1 years. The operation time, fracture reduction time, total incision length, intraoperative blood loss, Rasmussen knee function score and maximum active range of knee motion were compared between the 2 groups.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability between the groups ( P>0.05). The operation time [(158.6±26.0) min], fracture reduction time [(61.6±9.6) min], and total incision length [16.0 (13.3, 17.0) cm] in the observation group were significantly shorter than those in the control group [(199.9±60.9) min, (73.8±17.2) min, and 20.0 (17.0, 21.8) cm]; the intraoperative blood loss [175.0 (100.0, 200.0) mL] in the observation group was significantly less than that in the control group [200.0 (162.5, 387.5) mL]; the maximum active ranges of knee motion at one week and one month in the observation group were 94.9°±12.0° and 113.8°±14.1°, significantly larger than those in the control group (78.3°±14.6° and 96.8°±11.4°) (all P<0.05). Fractures achieved bony union at one year after operation in both groups. At 12 months after operation, there was no significant difference in the maximum active range of knee motion or the Rasmussen knee function score between the 2 groups ( P>0.05). Conclusion:In the treatment of Schatzker type Ⅵ tibial plateau fractures, compared with manual traction and open reduction, internal fixation with a reduction plate assisted by our self-designed lower extremity fracture traction reduction device can shorten operation time and total incision length, reduce intraoperative blood loss, and facilitate postoperative functional recovery of the knee for the patients.

19.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-955929

RESUMO

Hypertensive intracerebral hemorrhage is in the critical condition. Surgical treatment can promptly remove cranial hematoma, reduce the compression to the intracranial nerve, and improve the patient's neurological function and prognosis. At present, there are many operating modes, from the traditional large bone flap craniotomy to remove hematoma, to minimally invasive surgery. Each has its own advantages. This paper reviews various minimally invasive hematoma removal procedures and clinical nursing care based on traditional surgical treatment, analyzes the advantages and disadvantages of surgical treatment for patients with hypertensive cerebral hemorrhage, selects appropriate surgical methods and formulates reasonable surgical strategies.

20.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-955909

RESUMO

Objective:To investigate the efficacy of different surgical treatments for hypertensive cerebral hemorrhage in older adult patients and their effects on traumatic stress and cerebral edema.Methods:A total of 100 older adult patients with hypertensive cerebral hemorrhage who received treatment in Zhejiang Xin'an International Hospital from January 2018 to June 2020 were included in this study. They underwent either craniotomy (craniotomy group, n = 50) or hard channel minimally invasive puncture drainage (minimally invasive puncture group, n = 50) according to the willingness of patients and their close relatives. Perioperative indexes, Barthel index after treatment, nerve injury indexes before and after treatment, prognosis related indexes, trauma stress indexes and brain edema were compared between the two groups. Results:Operative time, intraoperative blood loss and postoperative hospital stay in the craniotomy group were (147.21 ± 31.35) minutes, (289.74 ± 22.75) mL and (42.74 ± 6.82 ) days, respectively, which were significantly longer or greater than (41.88 ± 7.19) minutes, (4.62 ± 0.88) mL and (16.27 ± 4.02) days in the minimally invasive puncture group ( t = 38.73, 62.17, 23.17, all P < 0.001). Barthel index at 1 and 3 months after treatment in the minimally invasive puncture group was (63.11± 9.64) and (93.51 ± 11.38), respectively, which was significantly greater than (44.78 ± 8.85) and (81.29 ± 10.37) in the craniotomy group ( t = 3.17, 6.21, both P < 0.05). Before treatment, there were no significant differences in nerve injury index, prognosis index, trauma stress index and brain edema between the two groups (all P > 0.05). At different time points after treatment, each indicator in the minimally invasive puncture group was significantly superior to that in the craniotomy group (all P < 0.05). Conclusion:Hard channel minimally invasive puncture drainage exhibits advantages over traditional craniotomy in the treatment of hypertensive cerebral hemorrhage in older adult patients. Hard channel minimally invasive puncture drainage can more greatly reduce injury to brain tissue, better control nerve injury and brain edema, and more remarkably improve patient's quality of life than traditional craniotomy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...